LEGRAND DAKER DK Plus

SPHINX in Europa
IT
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • ES
  • SE
  • CH
  • UK
Gruppi di prodotti > USV (UPS) > LEGRAND DAKER DK Plus

LEGRAND DAKER DK Plus

Single-phase conventional UPS systems from 1 to 10 kVA

LEGRAND DAKER DK Plus
5957_18672.png
5957_18673.jpg
5957_18674.jpg
5957_18676.jpg
5957_18677.jpg
5957_18678.jpg
5957_18679.jpg
5957_18680.jpg
  • ProprietàProprietà
  • DescrizioneDescrizione
  • Further informazioniFurther informazioni
  • PDFPDF
  • Single-phase conventional UPS systems
  • Power from 1 to 10 kVA
  • Power factor 0,9 for 1000-3000, 1 for 5000-10000
  • VFI-111 on-line double conversion
  • User-friendly display
  • Matching battery compartment to increase the uptime
  • Smart battery management
  • Optional automatic and manual bypass
  • The battery can easily be replaced by the user

Daker DK UPS Plus is a single phase uninterruptible power supply with high frequency PWM technology, Double Conversion OnLine.

It delivers a rated power of 1000-2000-3000-5000-6000-10000VA, equipped with valve-regulated, hermetically-sealed accumulator batteries, contained in a specific compartment inside the UPS or in one or more external cabinets.

With the reversible screen, the Daker DK Plus UPS can be used in both tower and 19" rack configuration.


Functions

  • View of the status, system parameters, charging status of the battery and faults.
  • Built-in communication software to control the UPS and stop it in the event of a fault and to perform remote diagnostics of the main functions.
  • Communication through SNMP/internet/network adaptor.
  • Optional slot for network configuration.
  • WEB/SNMP boards and relay interface that can provide isolated contacts for applications on industrial control panels or remote alarm panels.
  • Automatic and manual bypass (optional) to ensure constant power supply for critical loads in the event of an electronic fault, overload or overheating or scheduled maintenance.
  • Maintenance bypass switch (MTBS).
ProdGrafik

Characteristics



General characteristics
Convertible UPS with batteries
3 101 70 3 101 71 3 101 72 3 101 73 3 101 74
Nominal power (VA) 1000 2000 3000 5000 6000
Active power (W) 900 1800 2700 5000 6000
Technology On-line double conversion VFI-SS-111
Waveform Sinusoidal
Architecture Convertible tower and 19" rack
Input characteristics
Input voltage 230 V
Input frequency 50-60 Hz ± 5% autosensing
Input voltage range 176V - 280V at full load
THD of input current < 3%
Input power factor > 0,99
Output characteristics
Output voltage 230 V ± 1%
Output frequency
(nominal)
50/60 Hz (configurable via LCD panel) +/- 0.1%
Efficiency up to 90% up to 91% up to 92% up to 94%
Peak factor 1:3
THD of output voltage < 3% with linear load
Output voltage tolerance ± 1%
Internal automatic bypass included
External maintenance bypass optional
Batteries
Backup time extension Yes
Backup time (min) 9 10 7 6 5
Communication and management
Screen and
signalling
Four buttons and five LEDs for real-time control of the status and the main parameters of the UPS
Communication ports RS232 and USB serial ports
Remote control Available
Connector for network interface SNMP
Back feed protection yes
Emergency power off (EPO) yes
Mechanical characteristics
Dimensions
W x H x D (mm)
440 x 88 (2U) x 405 440 x 88 (4U)x 600 440 x 196(4U) x 680
Net weight (kg) 16 29,5 30 60 60
Dimensions of battery cabinet
H x W x D (mm)
440 x196(4U)x425 440 x 88 (2U) x 600 440 x 88 (2U) x 680
Ambient conditions
Ambient operating
temperature (°C)
0 to 40°C
Protection index IP 21
Relative humidity (%) 20 to 80%
Noise at 1 m (dBA) < 50
Heat dissipation (BTU/h) 490 654 818 892 1300
Certifications
Reference product
standards
EN 62040-1, EN 62040-2, EN 62040-3





General characteristics
Convertible UPS without batteries
3 101 75 3 101 76 3 101 77 3 101 78
3-1 version
Nominal power (VA) 5000 6000 10000 10000
Active power (W) 5000 6000 10000 9000
Technology On-line double conversion VFI-SS-111
Waveform Sinusoidal
Architecture Convertible tower and 19" rack
Input characteristics
Input voltage 230 V 380V 3P+N
Input frequency 50-60 Hz ± 5% autosensing
Input voltage range 176V - 280V at full load 305V - 485V
THD of input current < 3%
Input power factor > 0,99 > 0,9
Output characteristics
Output voltage 230 V ± 1%
Output frequency
(nominal)
50/60 Hz (configurable via LCD panel) +/- 0.1%
Efficiency up to 94% up to 90%
Peak factor 1:3
THD of output voltage < 3% with linear load
Output voltage tolerance ± 1%
Internal automatic bypass included
External maintenance bypass optional -
Batteries
Backup time extension Yes
Backup time (min) - - - -
Communication and management
Screen and
signalling
Four buttons and five LEDs for real-time control of the status and the main parameters of the UPS
Communication ports RS232 and USB serial ports RS232 serial ports
Remote control Available
Connector for network interface SNMP
Back feed protection yes
Emergency power off (EPO) yes
Mechanical characteristics
Dimensions
W x H x D (mm)
440x88(2U)x680 440x132 (3U) x680
Net weight (kg) 25* 25 26 28
Dimensions of battery cabinet
H x W x D (mm)
440x88(2U)x680 440x132 (3U) x680
Ambient conditions
Ambient operating
temperature (°C)
0 to 40°C
Protection index IP 21
Relative humidity (%) 20 to 80%
Noise at 1 m (dBA) < 50
Heat dissipation (BTU/h) 892 1300 1636
Certifications
Reference product
standards
EN 62040-1, EN 62040-2, EN 62040-3






ORDERING INFORMATIONS


Avaibles Modules
Convertible UPS with batteries
Cat. No. Nominal power (VA) Active power (W) Back-up time (min) Weight (kg)
3 101 70 1000 900 9 16
3 101 71 2000 1800 10 29,5
3 101 72 3000 2700 7 30
3 101 73 5000 5000 6 60
3 101 74 6000 6000 5 60



Avaibles Modules
Convertible UPS without batteries
Cat. No. Nominal power (VA) Active power (W) Back-up time (min) Weight (kg)
3 101 75 5000 5000 - 25
3 101 76 6000 6000 - 25
3 101 77 10000 10000 - 26
3 101 78
3-1 version
10000 9000 - 28