Perle IOLAN STG4 P Secure Terminal Servers

PoE Terminal Servers

Perle IOLAN STG4 P Secure Terminal Servers
6582_21547.png
6582_21548.jpg
  • ProprietàProprietà
  • DescrizioneDescrizione
  • Further informazioniFurther informazioni
  • PDFPDF
  • 4 port RS232 on RJ45 Ports
  • 10/100 or 10/100/1000 Ethernet
  • Small compact size
  • PoE powered using 802.3af compliant power sources
  • Wall, desk or DIN Rail mounting
  • Advanced security feature set

Engineers and Project Managers that require a cost effective power over Ethernet powered 4 port serial RS232-to-Ethernet Solution that maintains serial device protocol integrity across Ethernet must consider the IOLAN STG/STS. Having the highest performance processor available along with the Perle’s unique TrueSerialTM technology, the IOLAN STG/STS will provide the most authentic serial connections across Ethernet.

Ideal for

  • Engineers and Project Managers requiring a high performance serial to Ethernet interface for up to 4 serial RS232 based devices. Connect to serial based applications over Ethernet
  • IT Professionals requiring a cost-effective 4 port Terminal Server or serial Console Server for out of band management of IT equipment located in smaller data centers or remote sites
  • Organizations that need to deploy equipment in locations that are difficult or too costly to have separate AC power installed such as ceilings, walls and kiosks



Why the IOLAN STG/STS Terminal Server is the preferred choice:

  • High performance processors for the best throughput available. Ideal for time sensitive applications
  • Compact size offers the smallest 4 port serial to Ethernet solution on the market
  • Fully compliant with 802.3af PoE compliant power sources ( data or unused Ethernet pins )
  • Next Generation IP support (IPv6) for investment protection and network compatibility
  • TrueSerial™ packet technology – the most authentic serial connections across Ethernet ensures serial protocol integrity
  • Primary/Backup host functionality enables automatic connections to alternate hosts should the primary TCP connection go down
  • EasyPort Web – Access equipment serial console ports by using your java-enabled Internet browser
  • TruePort – Perle’s com/tty redirector for serial based applications operates on Windows, Vista, Linux, Solaris, SCO and Unix
  • Clustering – Provides a single view of all out of band console ports. Ideal for large data centers
  • FIPS 140-2 – Cryptographic modules meet US Government NIST compliancy
  • Dynamic DNS – Easy console management access from anywhere on the Internet
  • Intelligent Power cycling of equipment with Perle Remote Power Switches
  • Java-free browser access to remote serial console ports via Telnet and SSH
  • Ping watchdog probes enable customers to power cycle equipment with attached Perle RPS power switches in the event of an unresponsive networking gear
  • Lifetime warranty – best investment protection available
ProdGrafik



Hardware Specifications - IOLAN STG and STS PoE Terminal Servers

IOLAN STG4-P IOLAN STS4-P
Processor 600 Mhz ARM processor MPC852T, 66 Mhz, 87 MIPS
Memory
RAM MB 512 32
Flash MB 4000 8
Interface Ports
Number of Serial Ports 4
Serial Port Interface RS232 DTE on RJ45
Sun / Solaris Sun / Oracle ‘Solaris' Safe - no "break signal" sent during power cycle causing costly server re-boots or downtime
Serial Port Speeds 300bps to 230Kbps with customizable baud rate support 50bps to 230Kbps with customizable baud rate support
Data Bits 5,6,7,8, 9-bit protocol support
Parity Odd, Even, Mark, Space, None
Flow Control Hardware, Software, Both, None
Serial Port Protection 15Kv Electrostatic Discharge Protection (ESD)
Local Console Port RS232 on RJ45 with DB9 adapter (provided)
Network Autosensing 1000Base-T / 100Base-TX / 10Base-T
Auto-MDIX
10/100Base-TX Ethernet RJ45
Software selectable Ethernet speed 10/100/1000/Auto Software selectable Ethernet speed 10/100/Auto
Software selectable Half/Full/Auto duplex
Ethernet Isolation 1.5Kv Magnetic Isolation
Power
Power over Ethernet 802.3af PoE compliant data pins (1/2, 3/6 or unused pins 4/5, 7/8) (48v DC)
Power Supply Options Power via External power 9-30v DC, 4.8 Watts uses standard 5.5mm x 9.5mm x 2.1mm barrel socket,
Power IN over serial cable
Nominal Input Voltage 12v DC / 24v DC on Barrel Connector
Input Voltage Range 9-30v DC on Barrel Connector
Power External Device
via Serial Port
+5v DC regulated, 1W max
Typical Power Consumption
'@ 12v DC ( Watts )
2 2.4
Indicators
LEDs Power/System Ready
Network Link activity
Serial: Transmit and Receive data per port
Environmental Specifications
Heat Output (BTU/HR) 16.38 8.2
MTBF ( hours ) 184,554 169,753
Calculation model based on MIL-HDBK-217-FN2 @ 30 °C
Operating Temperature 0C to 55C, 32F to 131F
Storage Temperature -40C to 85C, -40F to 185F
Humidity 5 to 95% (non condensing) for both storage and operation.
Case SECC Zinc plated sheet metal (1 mm)
Ingress Protection Rating IP30
Mounting Wall mount - bracket included
DIN Rail bracket optional
Product Dimensions
Weight 0.35 kg (.77 lbs)
Dimensions 112 x 82 x 28 (mm), 4.4 x 3.2 x 1.1 (in)
Packaging
Shipping Weight .54 kg (1.2 lbs)
Shipping Dimensions 260 x 170 x 70 (mm), 10.2 x 6.7 x 2.8 (in)
Regulatory Approvals
Emissions CFR47 FCC Part 15 Subpart B:2015 CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A
ICES-003:2016 Issue 6:2016 ICES-003, Issue 4, February 2004 (Canada)
CISPR 32:2015/EN 55032:2015 (Class A)
CISPR 32:2015/EN 55032:2015 (Class A)
EN61000-3-2:2014, Limited for Harmonic Current Emissions EN61000-3-2 : 2010, Limits for Harmonic Current Emissions
EN61000-3-3:2013, Limits of Voltage Fluctuations and Flicker EN61000-3-3 : 2010, Limits of Voltage Fluctuations and Flicker
Immunity CISPR 24:2010/EN 55024:2010
EN61000-4-2: 2009 Electrostatic Discharge
EN61000-4-3: 2006/A2:2010: RF Electromagnetic Field Modulated
EN61000-4-4: 2004 Fast Transients
EN61000-4-5: 2006 Surge
EN61000-4-6: 2009 RF Continuous Conducted
EN61000-4-8: Power-Frequency Magnetic Field
EN61000-4-11: Voltage Dips and Voltage Interruptions
Safety IEC 62368-1 and EN 62368-1:2014 IEC 60950-1 (ed 2); am1 am2 and EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013
CAN/CSA-C22.2 No. 62368-1-14 and UL 62368-1 CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1, Second Edition
Other Reach, RoHS and WEEE Compliant
Directive 2011/65/EU restriction of the use of certain hazardous substances in electrical and electronic equipment and meets the following standard:: EN 50581:2012
CCATS - G168388
ECCN - 5A992
HTSUS Number: 8471.80.1000
Perle Lifetime warranty




Serial Connector Pinout

IOLAN DTE

RJ45 Socket

IOLAN RJ45 Socket Function Direction
1 Power In in
2 DCD in
3 RTS out
4 DSR in
5 TXD out
6 RXD in
7 GND line
8 CTS in
9 DTR out
10 Power Out out




TCP

Using RAW TCP Sockets

A raw TCP socket connection which can be initiated from the serial-Ethernet device or from the remote host/server. This can either be on a point to point or shared basis where a serial device can be shared amongst multiple devices. TCP sessions can be initiated either from the TCP server application or from thePerle IOLAN serial-Ethernet adapter.

UDP

Using Raw UDP Sockets

For use with UDP based applications, Perle IOLANs can convert serial equipment data for transport across UDP packets either on a point to point basis or shared across multiple devices.

Console Server

Console Management

For access to remote console ports on routers, switches,etc, Perle IOLAN’s enable administrators secure access to these RS232 ports via inband Reverse Telnet / SSH or out of band with dial-up modems. Perle IOLAN models with integrated modems are available.

COM/TTY

Connect Serial-based Applications with a COM/TTY Port Driver

Serial ports can be connected to network servers or workstations running Perle's TruePort software operating as a virtual COM port. Sessions can be initiated either from the Perle IOLAN or from TruePort.

Tunneling

Serial Tunneling between two Serial Devices

Serial Tunneling enables you to establish a link across Ethernet to a serial port on another IOLAN. Both IOLAN serial ports must be configured for Serial Tunneling (typically one serial port is configured as a Tunnel Server and the other serial port as a Tunnel Client).

Virtual Modem

Virtual Modem

Enables the serial-Ethernet adapter to simulate a modem connection. When connected to the IOLAN and initiates a modem connection, the IOLAN starts up a TCP connection to another IOLAN serial-Ethernet adapter configured with a Virtual Modem serial port or to a host running a TCP application.




Ordering Information

    IOLAN STG4 P Device Server:

        4 x RJ45 connectors with RS232 interface, 10/100/1000 Ethernet, 802.3af Power over Ethernet (PoE) compliant, advanced data encryption, user authentication and event management security features included, IPv6, COM port redirector, 15kv ESD



    IOLAN STS4 P PoE Secure Device Server:

        4 x RJ45 connectors with RS232 interface, 10/100 Ethernet, 802.3af Power over Ethernet (PoE) compliant, desktop/wall mount, advanced data encryption, user authentication and event management security features included, IPv6, COM port redirector, 15kv ESD



I clienti che hanno visto questo prodotto hanno anche consultato
Accept

This website uses cookies to provide the best possible experience. More information.